Description: Wiring Device-Kellems, GFHW431, Hard Wired Gfci, 3-Phase 5-Wire Automatic Multi-Strand Fabricated, 120/208 VAC, 30 A, 60 Hz Frequency, -30 to 150 deg F, 0.025 s Response, NEMA 4X Enclosure, Thermoplastic, Yellow, 24 in L Dimensions

Manufacturer PN: GFHW431

UPC:  78358552109

Kendall Electric Inc PN: 4417114

Invoice Description:

WIRING GFHW431 30A 120/208 3-PH AUTO GFCI HW 120/208 3-PH AUTO GFCI HW


SPEC SHEET

▸ See All in Hard Wired GFCI

 

Wiring Device-Kellems GFHW431 3-Phase 5-Wire Automatic Multi-Strand Fabricated Hard Wired Gfci, 120/208 VAC, 30 A, NEMA 4X Enclosure, Thermoplastic

Log In for Pricing and Availability

Note: Lead times are estimates only

 
 

Description

Wiring Device-Kellems, GFHW431, Hard Wired Gfci, 3-Phase 5-Wire Automatic Multi-Strand Fabricated, 120/208 VAC, 30 A, 60 Hz Frequency, -30 to 150 deg F, 0.025 s Response, NEMA 4X Enclosure, Thermoplastic, Yellow, 24 in L Dimensions

Specifications

 Amperage Rating 30 A
 Application Industrial, Commercial and Wire into Circuit Applications
 Brand Name Hubbell Premise Wiring
 Color Yellow
 Dimensions 24 in L
 Enclosure NEMA 4X
 Frequency Rating 60 Hz
 Includes Foam Gasket, Mounting Template and Detailed Instructions
 Manufacturer Part Number GFHW431
 Material Thermoplastic
 Response Time 0.025 s
 Standards/Approvals cULus Listed|UL 943
 Temperature Rating -30 to 150 deg F
 Type 3-Phase 5-Wire Automatic Multi-Strand Fabricated
 Voltage Rating 120/208 VAC

Features

▪ Class A GFCI, 10000 cycles (6000 with load and 4000 without load) life
▪ Green light on power on, red blinking light plus optional audible alarm power off indicator
▪ Copper conductor
▪ 0.95 maximum humidity
▪ Trips if ground and neutral touch at load side
▪ Open neutral protection Trips upon loss of neutral
▪ Automatically energizes or sets the GFCI for use once power is applied to the circuit
▪ After a ground fault condition, unit must be reset by pushing the reset button
▪ This feature eliminates the need for the unit to be reset each time the power is turned ON
▪ Automatic reset is ideal where temporary power failure is likely and undesirable such as waste water treatment plants, portable signs and some pump applications
▪ Offers a 4 to 6 mA trip level
▪ Red light begins blinking when a ground fault is detected and the output power is interrupted
▪ 6 Ohm or less grounded neutral detection
▪ Double insulated switch interface, electromagnetic latching mechanism
▪ Yellow background with black lettering label color
 