Page Loading...
ABB
  • THQB2120GFT GE THQB 2P 120/240V 20A GFCI SELF-TEST
  • THQB2120GFT GE THQB 2P 120/240V 20A GFCI SELF-TEST
  • THQB2120GFT GE THQB 2P 120/240V 20A GFCI SELF-TEST
  • THQB2120GFT GE THQB 2P 120/240V 20A GFCI SELF-TEST
  • THQB2120GFT GE THQB 2P 120/240V 20A GFCI SELF-TEST

Description: GE Molded Case Circuit Breaker, Type THQB, 120/240 V AC, 20 A, 50 to 60 Hz, 10 kA Interrupt, Q-Line Frame, Thermal Magnetic Trip, 2 Pole, 1 ph, Pivot Handle Actuator, Load Lug, 14 to 8 AWG, 12 to 8 AWG Wire, Bolted-On Mount, 10 to 50 deg C, 2 in W x 2-3/8 in D x 3-9/32 in H, Plastic

Manufacturer PN: THQB2120GFT

UPC:  78316448555

Kendall Electric Inc PN: 3546525

Invoice Description:

THQB2120GFT GE THQB 2P 120/240V 20A GFCI SELF-TEST


SPEC SHEET

▸ See All in Ground-Fault Circuit Breakers

 

GE THQB2120GFT Type THQB Molded Case Circuit Breaker, 120/240 V AC, 20 A, 10 kA Interrupt, 2 Poles, Thermal Magnetic Trip

Log In for Pricing and Availability

Note: Lead times are estimates only

 
 

Description

The National Electrical Code requires ground fault circuit interrupter (GFCI) protection of receptacles located outdoors, in bathrooms, garages and spa areas. This applies not only to new construction, but also to existing homes. The GFCI circuit interrupter provides protection against overloads, short circuits and ground faults. It detects very low levels of electrical current leakage (ground faults) and acts quickly to shut off power, preventing serious shock.
GE Molded Case Circuit Breaker, Type THQB, 120/240 V AC, 20 A, 50 to 60 Hz, 10 kA Interrupt, Q-Line Frame, Thermal Magnetic Trip, 2 Pole, 1 ph, Pivot Handle Actuator, Load Lug, 14 to 8 AWG, 12 to 8 AWG Wire, Bolted-On Mount, 10 to 50 deg C, 2 in W x 2-3/8 in D x 3-9/32 in H, Plastic

Specifications

 Actuator Type Pivot Handle
 Amperage Rating 20 A
 Application Outdoor Applications
 Brand Name GE
 Connection Type Load Lug
 Dimensions 2 in W x 2-3/8 in D x 3-9/32 in H
 Frame Q-Line
 Frequency Rating 50 to 60 Hz
 Manufacturer Part Number THQB2120GFT
 Material Plastic
 Mounting Type Bolted-On
 Number of Poles 2
 PART NUMBER KEYWORDS THQB2120GFT ; 13207497 ; 783164485554 ; 78316448555 ; 00783164485554
 Phase 1
 Standards/Approvals HACR Rated|UL File No. E11592/E51075
 Temperature Rating 10 to 50 deg C
 Type Type THQB
 Voltage Rating 120/240 V AC

Features

▪ Copper stabs, tin plated for corrosion resistance, make the connection reliable and permanent
▪ Heat resistant thermoset cases and covers add stability and structural rigidity
▪ Trips are easy to spot because handles trip to the center position
▪ The dedicated calibration screw is cemented (not simply papered over) to prevent shifting, the result is stable calibration for optimum trip performance
▪ Class A (5 mA ground fault trip level)
▪ 14 to 8 AWG (Cu), 12 to 8 AWG (Al) wire range
▪ 10 kA at 120 VAC interrupt rating

Resources

 Catalog Page 
 Product Data Sheet 
 
Time Zone 
 
 
 