Description: Bussmann CUBEFuse™ Low-Peak™ Time Delay Fuse, Finger Safe Inrush Current Withstand Non-Indicating, Series: TCF, 60 A, 600 VAC/300 VDC, 100/300 kA Interrupt, Class: CF, 10 s at 500% Response, Blade Terminal, Chassis/DIN Rail Mount, Square Blade Body Type, Dual Element, Glass Filled Polyethersulfone, 0.81 in Dia x 5 in L Body Size

Manufacturer PN: TCF60RN

UPC:  05171222255

Kendall Electric Inc PN: 2691029

Invoice Description:

TCF60RN BUS TCF FUSE 60A CUBE NON-IND (1)


SPEC SHEET

▸ See All in Time Delay Fuses

 

Bussmann CUBEFuse™ Low-Peak™ TCF60RN Finger Safe Inrush Current Withstand Non-Indicating Time Delay Fuse, 60 A, 600 VAC/300 VDC, 100/300 kA Interrupt, Class: CF, Square Blade Body

Log In for Pricing and Availability

 
 

Description

The revolutionary BussmannTM series Low-PeakTM CUBEFuseTM delivers the smallest footprint compared to any Class CC, J or RK fuse solution — requiring up to 70 less space when combined with its unique fuse holder or UL 98 Listed Compact Circuit Protector switch. Freeing up space is powerful. And the CUBEFuse does just that, while packing up to a 300 kA interrupting rating and enabling higher equipment short-circuit current rating (SCCR). Available from 1 to 400 amps.
Bussmann CUBEFuse™ Low-Peak™ Time Delay Fuse, Finger Safe Inrush Current Withstand Non-Indicating, Series: TCF, 60 A, 600 VAC/300 VDC, 100/300 kA Interrupt, Class: CF, 10 s at 500% Response, Blade Terminal, Chassis/DIN Rail Mount, Square Blade Body Type, Dual Element, Glass Filled Polyethersulfone, 0.81 in Dia x 5 in L Body Size

Specifications

 Amperage Rating 60 A
 Application Commercial/Institutional Buildings/structures, Power Distribution and Control, Electrical Panel Boards, Industrial Control, Machinery Disconnects and Required Finger safe systems Applications, Safety and Security Systems, Stationary Machinery and Equipment Outside Factory
 Body Size 0.81 in Dia x 5 in L
 Body Type Square Blade
 Brand Name Bussmann
 Class CF
 Element Dual
 Manufacturer Part Number TCF60RN
 Material Glass Filled Polyethersulfone
 Mounting Type Chassis/DIN Rail
 Response Time 10 s at 500%
 Series TCF
 Standards/Approvals CE Certified|CSA 1422- 02/File No. 53787|RoHS Compliant|UL File No. E4273|UL Guide JFHR
 Terminal Type Blade
 Type Finger Safe Inrush Current Withstand Non-Indicating
 Video Links 
 Voltage Rating 600 VAC/300 VDC

Features

▪ Robust cycling and inrush current withstand
▪ Low let through currents under fault conditions
▪ Provides type 2 "no damage" in protection for IEC® motors starters when properly sized
▪ Easy selective co-ordination with any other Cooper Bussmann Low-Peak™ class CC, L, J and RK1 fuse with simple 2:1 amp ration between upstream and downstream fuses
▪ 100 kAIC at 300 Vdc/300 kAIC at 600 Vac interrupt rating
▪ 10 s at 500% response time
▪ The world's first finger safe power fuse system
▪ Smallest footprint of any class fuse including class J, CC, T and RK
▪ Meets class CF and class J time delay electrical performance requirements
▪ The indicating version features easyID™ open fuse technology for faster troubleshooting and reduced downtime
▪ Faster response to damaging faults to help reduce destructive thermal and magnetic forces
▪ True dual element fuse construction with a minimum of 10 s time delay at 500% of rating
▪ Long time delay minimizes nuisance circuit openings due to temporary overloads and transient surges
▪ High interrupt rating to safely interrupt faults up to 300 kA
▪ No venting of arc or molten metal and gases during opening
 