Page Loading...
Eaton
SC25 BUS 480VAC FUSE

Mouse over image to zoom, click to enlarge

  • SC25 BUS 480VAC FUSE
  • SC25 BUS 480VAC FUSE
  • SC25 BUS 480VAC FUSE

Description: Bussmann Fuse, Current Limiting Time Delay, Series: SC Series, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Rejection, 25 A, 480 V AC, 100/10 kAIC Interrupt, Class: G, 12 s at 200% Response, Ferrule End Terminal, Holder Mount, Cartridge Body Type, Melamine, 0.41 in Dia x 1.62 in L Body Size

Manufacturer PN: SC-25

UPC:  05171225025

Kendall Electric Inc PN: 23251

Invoice Description:

SC25 BUS 480VAC FUSE


SPEC SHEET

▸ See All in Class G Fuses

 

Bussmann SC-25 Current Limiting Time Delay Fuse, 25 A, 480 V AC, 100/10 kAIC Interrupt, G Class, Cartridge Body

Log In for Pricing and Availability

 
 

Description

Bussmann's SC type fuses are UL Class G and provide fast-acting (1/2-6 A) and time-delay (7-60 A) characteristics for circuit protection need. SC fuses are size rejecting in terms of their overall length thereby aiding in the prevention of overfusing
Bussmann Fuse, Current Limiting Time Delay, Series: SC Series, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Rejection, 25 A, 480 V AC, 100/10 kAIC Interrupt, Class: G, 12 s at 200% Response, Ferrule End Terminal, Holder Mount, Cartridge Body Type, Melamine, 0.41 in Dia x 1.62 in L Body Size

Specifications

 Amperage Rating 25 A
 Application Industrial Facilities and Factories, Safety and Security Systems, Fusible Branch Panel Boards, HV Branch Circuit Protection and General Purpose Applications
 Body Size 0.41 in Dia x 1.62 in L
 Body Type Cartridge
 Brand Name Bussmann
 Class G
 Indicating Non Indicating Non-Indicating
 Manufacturer Part Number SC-25
 Material Melamine
 Mounting Type Holder
 Rejection Non Rejection Rejection
 Response Time 12 s at 200%
 Series SC Series
 Standards/Approvals CE Marked,RoHS Compliant
 Terminal Type Ferrule End
 Type Current Limiting Time Delay
 Video Links 
 Voltage Rating 480 V AC

Features

▪ Most economical overcurrent protection solution compared to circuit breakers
▪ For use in various non-demanding, general purpose applications
▪ Compact branch circuit units with high interrupt rating and current limitation
▪ Size rejection by length helps prevent over fusing
▪ Fuses 7 A and above have a degree of overload time delay that permits them to pass temporary overloads
▪ 100 kA at 480 VAC, 10 kA at 300 VDC interrupt rating
 
Time Zone 
 
 
 