ABB
RC5-1/50 ABB A9-A40,SS,RC,24-50V PACK 2 EA

Mouse over image to zoom, click to enlarge

Description: ABB, RC5-1/50, Surge Suppressor, For Use With: AS09 to AS16 and A9 to A40 Across the Line Contactor, Specifications: 24 to 50 V AC, 32.4 mm L x 30.25 mm W x 10.5 mm H Dimensions

Manufacturer PN: RC5-1/50

UPC:  47152212124

Kendall Electric Inc PN: 2090433

Invoice Description:

RC5-1/50 ABB A9-A40,SS,RC,24-50V PACK 2 EA


SPEC SHEET

▸ See All in NEMA & IEC Contactors

 

ABB RC5-1/50 Surge Suppressor, For Use With AS09 to AS16 and A9 to A40 Across the Line Contactor

Log In for Pricing and Availability

Note: Lead times are estimates only

 
 

Please note: This product can only be sold to customers in our authorized sales territory. Please log into your account to see locally available product.

Description

RC5-1/50 is a RC type surge suppressor designed to reduce the maximum overvoltage peak value and to limit or even completely eliminate the high pre-damping voltage frequencies, when used with an AC operated conventional contactor for a rated control circuit voltage between 24 to 50 VAC 50/60 Hz. The operation of inductive circuits causes over voltages, in particular on opening of the contactor coil. The electromagnetic energy stored in the coil during contactor closing is restored on opening in the form of surges, the slope and amplitude of which may rise to several kilovolts. A number of drawbacks are observed ranging from interference on the electronic devices to breakdown of insulators and even destruction of certain sensitive components.
ABB, RC5-1/50, Surge Suppressor, For Use With: AS09 to AS16 and A9 to A40 Across the Line Contactor, Specifications: 24 to 50 V AC, 32.4 mm L x 30.25 mm W x 10.5 mm H Dimensions

Specifications

 Brand Name ABB
 Dimensions 32.4 mm L x 30.25 mm W x 10.5 mm H
 Manufacturer Part Number RC5-1/50
 PART NUMBER KEYWORDS RC5-1/50 ; RC5150 ; 1SBN050100R1000 ; 13558493 ; 662019883151 ; 66201988315 ; 00662019883151
 Specifications 24 to 50 V AC
 Standards/Approvals CE Certified|GOST Certified|RINA Certified|UL Listed|cUL Listed|GOST Certified|RINA Approved|UL Listed
 Suitable For Use With AS09 to AS16 and A9 to A40 Across the Line Contactor

Features

▪ The surge suppressor is clipped onto the top or side part in regards with the contactor or contactor relay base design without change in device overall dimensions
▪ No operating delays
▪ Very fast clipping attenuation of steep fronts and thus of high frequencies
 