| ▪ Time delay adjustment for delayed Off time settings of 30 sec (for walking test), 10, 20 and 30 min, allows customized adjustments to maximum energy savings |
| ▪ Light sensor adjustable ambient light override ranges from approximately 20 to 5000+ LUX to prevent lights from turning On automatically during periods of ample natural light, increasing energy savings |
| ▪ Light sensor enables the load hold Off feature once level has been set |
| ▪ Vacancy confirmation when the time out expires and the lights turns Off, a 30 sec vacancy confirmation exists to turn the lights back ON |
| ▪ False detection circuitry |
| ▪ Presentation mode feature for slide or film presentations allows pushbuttons to turn lights Off and keep them Off while the room is occupied |
| ▪ 1-unit can be used for 120 to 277 VAC lighting |
| ▪ Compatible with both electronic and magnetic ballasts |
| ▪ Relay switches at the zero crossing point of the AC power curve to ensure maximum contact life and compatibility with electronic ballasts |
| ▪ Exclusive Leviton® high inrush stability (HIS) circuitry, specifically designed to handle today's high inrush electronic ballast loads and offer unmatched durability and service |
| ▪ No neutral design is optional for retrofit applications |
| ▪ Fits in standard wallbox and replaces 1-pole wall switch, gangable with other units |
| ▪ Low profile design eliminates obtrusive scanning-device look |
| ▪ Convenient pushbutton provides manual ON/Off light switching at any time |
| ▪ Two dual element PIR sensors used to widen detection range |
| ▪ Segmented fresnel lens provides optimum sensitivity and performance designed with an extensive minor motion area where even slight body movements will be detected |
| ▪ Vandal-resistant PIR lens |
| ▪ Horizontal field-of-view may be adjusted between 180 and 60 deg of arc by using integral blinders located on either side of the lens, no masking tape required |
| ▪ Manual On/auto Off mode for installations where manual On switching is required but auto Off switching is still desired for CEC title T24 energy savings |
| ▪ To comply with T24, red LED indicator light flashes when sensor detects motion to verify detection is active |