K-276B-1120 EDWARDS FIRE ALARM PULL STATION, NON-CODED, BREAK GLASS, PLASTIC, SINGLE ACTION, SINGLE POLE, OPEN CIRCUIT, SCREW TERMINAL, KEY RESET.

Mouse over image to zoom, click to enlarge

Description: Edwards Signaling™ Kidde Fire Alarm Pull Station, Single Action Non-Coded, Series: K-276B, 30 V AC/28 V DC, 1/3 A, 5-3/16 in Height, 3-9/16 in Width, 3-3/8 in Depth, 32 to 120 deg F, 95% Relative Humidity Humidity, For Use With: Conventional Fire Alarm System, Specifications: 1-Pole Alarm, Open Circuit Switch, Screw Terminal Connection, Specifications Met: CSFM Approved, Lexan®, Flush Mounting, Red

Manufacturer PN: K-276B-1120

UPC:  79301605139

Kendall Electric Inc PN: 3685225

Invoice Description:

K-276B-1120 EDWARDS FIRE ALARM PULL STATION, NON-CODED, BREAK GLASS, PLASTIC, SINGLE ACTION, SINGLE POLE, OPEN CIRCUIT, SCREW TERMINAL, KEY RESET.

 

Edwards Signaling™ Kidde K-276B-1120 K-276B Single Action Non-Coded Fire Alarm Pull Station With Keyed Reset, 30 V AC/28 V DC, 1/3 A, 32 to 120 deg F, CSFM Approved, Lexan®

Log In for Pricing and Availability

Note: Lead times are estimates only

 
 

Description

The Kidde Cat. No. 276B/277B series non-coded fire alarm stations are contemporary styled Lexan® stations and are flexibly designed to meet a wide variety of application requirements and operational sequences. The Cat. No. 276B series are single action stations with terminals for field wiring connections. All types can be either pre-signal or general alarm and are available with single or double pole alarm contacts which can be normally open, normally closed or a combination or both. Either a key or tool (depending on station selected) is required to reset mechanism. See specification chart for specific catalog numbers and features. For semi-flush mounting use a standard North American 4 in square box with a single gang plaster cover having an overall minimum depth of 2-1/4 in. For surface mounting use a Cat. No. K-276B-RSB surface back box.
Edwards Signaling™ Kidde Fire Alarm Pull Station, Single Action Non-Coded, Series: K-276B, 30 V AC/28 V DC, 1/3 A, 5-3/16 in Height, 3-9/16 in Width, 3-3/8 in Depth, 32 to 120 deg F, 95% Relative Humidity Humidity, For Use With: Conventional Fire Alarm System, Specifications: 1-Pole Alarm, Open Circuit Switch, Screw Terminal Connection, Specifications Met: CSFM Approved, Lexan®, Flush Mounting, Red

Specifications

 Amperage Rating 1/3 A
 Brand Name Edwards Signaling™
 Color Red
 Depth 3-3/8 in
 Height 5-3/16 in
 Humidity 95% Relative Humidity
 Manufacturer Part Number K-276B-1120
 Material Lexan®
 Mounting Type Flush
 PART NUMBER KEYWORDS K-276B-1120 ; K276B1120 ; 793016051394 ; 79301605139 ; 00793016051394
 Series K-276B
 Specifications 1-Pole Alarm, Open Circuit Switch, Screw Terminal Connection
 Specifications Met CSFM Approved
 Standards/Approvals UL Listed
 Suitable For Use With Conventional Fire Alarm System
 Temperature Rating 32 to 120 deg F
 Type Single Action Non-Coded
 Voltage Rating 30 V AC/28 V DC
 Width 3-9/16 in

Features

▪ 3 A at 30 VAC, 1 A at 28 VDC current rating
▪ Single action models
▪ Single or double pole contacts
▪ Terminals or wire leads for field connections
▪ Pre-signal or general alarm operation
▪ Key lock or tool reset
▪ Break glass operation
▪ Contemporary styling
▪ Rugged Lexan® construction
▪ Latch action until reset