HMCP030H1CA04M01 CH SERIES C, F-FRAME MOTOR CIRCUIT PROTECTOR

Mouse over image to zoom, click to enlarge

Description: EATON Motor Circuit Protector, HMCP, Series: C Series, 600 VAC, 250 VDC, 30 A, F Frame, Magnetic Trip, 90 to 300 A Trip, 3 Pole, Line/Load Connection, 1A-1B Auxiliary, NEMA 1 Enclosure, 3.38 in L x 4.13 in W x 6 in H Dimensions

Manufacturer PN: HMCP030H1CA04M01

UPC:  78667909110

Kendall Electric Inc PN: 3660358

Invoice Description:

HMCP030H1CA04M01 CH SERIES C, F-FRAME MOTOR CIRCUIT PROTECTOR


SPEC SHEET

▸ See All in Motor Protection Circuit Breakers

 

EATON HMCP030H1CA04M01 C Series HMCP Motor Circuit Protector, 600 VAC, 250 VDC, 30 A, 3 Poles, Magnetic Trip

Log In for Pricing and Availability

Note: Lead times are estimates only

 
 

Description

Eaton’s Electrical Sector under the Eaton brand offers the widest variety of molded case circuit breakers available today. Designed for electrical and machinery OEMs serving a range of industries and applications these proven designs incorporate the latest in innovation with the high reliability that has been our hallmark since the advent of the circuit breaker in the 1920s
EATON Motor Circuit Protector, HMCP, Series: C Series, 600 VAC, 250 VDC, 30 A, F Frame, Magnetic Trip, 90 to 300 A Trip, 3 Pole, Line/Load Connection, 1A-1B Auxiliary, NEMA 1 Enclosure, 3.38 in L x 4.13 in W x 6 in H Dimensions

Specifications

 Amperage Rating 30 A
 Auxiliary Contact Rating 1A-1B
 Brand Name EATON
 Connection Type Line/Load
 Dimensions 3.38 in L x 4.13 in W x 6 in H
 Enclosure NEMA 1
 Frame F
 Manufacturer Part Number HMCP030H1CA04M01
 Number of Poles 3
 Series C Series
 Standards/Approvals CSA Certified|UL Listed
 Trip Range 90 to 300 A
 Type HMCP
 Video Links 
 Voltage Rating 600 VAC/250 VDC

Features

▪ Convenient dial adjustment allows the user to select from eight different current levels for precise motor circuit protection
▪ High short circuit current ratings can be achieved without the need for fuses or additional limiters, reducing both space and spare parts requirements
▪ Motor inrush trip suppressor allows the starting of high efficiency motors without sacrificing sensitive levels of short circuit protection
▪ Clears low-level faults (the most common type of fault in a motor circuit) more effectively than fuses, preventing faults from cascading and damaging equipment
▪ Easily test without having to replace the device (unlike fusible devices) by depressing a push to trip mechanism on the cover
 