Description: Crouse-Hinds Conduit Junction Box, Series: GUB, 8 in x 10 in x 5-7/8 in Size, For Use With: Threaded Rigid Conduit, Copper-Free Aluminum, Natural

Manufacturer PN: GUB02SA

UPC:  78227446981

Kendall Electric Inc PN: 3998014

Invoice Description:

GUB02SA C-HINDS HAZLOC AL JUNC BX THRD CVR 8X10X5 7/8 CN


SPEC SHEET

▸ See All in Conduit Junction Boxes

 

Crouse-Hinds GUB02 SA Conduit Junction Box, 8 in x 10 in x 5-7/8 in, For Use With Threaded Rigid Conduit, Copper-Free Aluminum

Log In for Pricing and Availability

Note: Lead times are estimates only

 
 

Description

Crouse-Hinds series GUE and GUB explosionproof junction boxes are used in threaded rigid conduit systems in hazardous areas to function as a splice box, pull box or equipment and device enclosure, to house wiring, and are used indoors and outdoors.
Crouse-Hinds Conduit Junction Box, Series: GUB, 8 in x 10 in x 5-7/8 in Size, For Use With: Threaded Rigid Conduit, Copper-Free Aluminum, Natural

Specifications

 Application Hazardous Areas, House Relays, Contactors, Terminal Blocks or Other Equipment, Indoor/Outdoor, Industry Facilities, Factories, Power Distribution and Control Applications
 Brand Name Crouse-Hinds
 Finish Natural
 Manufacturer Part Number GUB02 SA
 Material Copper-Free Aluminum
 PART NUMBER KEYWORDS GUB02 SA ; GUB02SA ; 782274469812 ; 78227446981 ; 00782274469812
 Series GUB
 Size 8 in x 10 in x 5-7/8 in
 Standards/Approvals UL 1203|CSA C22.2 No. 30|NEC Certified|CEC Class I, Division 1/2, Group C/D, Class II, Division 1, Group E/F/G, Class II, Division 2, Group F/G, Class III
 Suitable For Use With Threaded Rigid Conduit

Features

▪ Threaded construction throughout permits use in hazardous areas
▪ Bodies have thick walls so they can be factory or field drilled and tapped to meet National Electric Code®/CEC requirements for class I hazardous areas
▪ Covers are provided with a neoprene O-ring gasket to meet NEMA/EEMAC 4 requirements for a watertight seal
▪ Internal grounding lug provides a means to ground enclosed equipment
▪ Boxes are machined for field installed mounting plates
▪ GUB boxes are ATEX certified when ordered with suffix SA ATEX
▪ Explosionproof, dust ignitionproof and raintight
▪ 7 in cover opening
▪ Without hub
 