Eaton
GFR1200E CH GFR RELAY ELECTRICAL RESET W ZONE INTERLOCKING_100-1200A STYLE#1293C47G04

Mouse over image to zoom, click to enlarge

Description: EATON Ground Fault Relay, Electrical Reset, Series: GFR, 120 V AC, Specifications: 50 to 60 Hz, 100 to 1200 A Ground Current, Surface Mounting, 8.1 in L x 4.1 in W x 5.3 in H Dimensions

Manufacturer PN: GFR1200E

UPC:  78667991022

Kendall Electric Inc PN: 3808668

Invoice Description:

GFR1200E CH GFR RELAY ELECTRICAL RESET W ZONE INTERLOCKING_100-1200A STYLE#1293C47G04


SPEC SHEET

▸ See All in Ground Fault Relay

 

EATON GFR1200E Electrical Reset Ground Fault Relay, 120 V AC, 50 to 60 Hz, 100 to 1200 A Ground Current, Surface Mount

Log In for Pricing and Availability

Note: Lead times are estimates only

 
 

Description

A type GFR ground fault protection system, when properly installed on a grounded electrical system, will sense phase-to-ground fault currents. When the level of fault current is in excess of the pre-selected current pickup and time delay settings, the GFR relay will initiate a trip action of a disconnect device, which will open the faulted circuit and clear the fault. The GFR devices are UL class 1 devices designed to protect electrical equipment against extensive damage from arcing ground faults. A basic type GFR ground fault protection system consists of a ground fault relay, a ground fault current sensor and a disconnect device equipped with a shunt trip device. This disconnect device can be a molded case circuit breaker, a power circuit breaker, a bolted pressure switch or other fusible disconnect device, suitable for application with UL class 1 ground fault sensing and relaying equipment.
EATON Ground Fault Relay, Electrical Reset, Series: GFR, 120 V AC, Specifications: 50 to 60 Hz, 100 to 1200 A Ground Current, Surface Mounting, 8.1 in L x 4.1 in W x 5.3 in H Dimensions

Specifications

 Application For circuit protection
 Brand Name EATON
 Dimensions 8.1 in L x 4.1 in W x 5.3 in H
 Manufacturer Part Number GFR1200E
 Mounting Type Surface
 Series GFR
 Specifications 50 to 60 Hz, 100 to 1200 A Ground Current
 Standards/Approvals CSA Certified|UL Listed
 Type Electrical Reset
 Voltage Rating 120 V AC

Features

▪ One current sensor
▪ One relay unit
▪ One circuit breaker or disconnect device with shunt trip or a shunt trip attachment for mounting in existing breaker
▪ Optional test panel