GFHW33115 HUBBELL HW GFCI, 30A 120/240V, AUTO, W/ENUN

Mouse over image to zoom, click to enlarge

  • GFHW33115 HUBBELL HW GFCI, 30A 120/240V, AUTO, W/ENUN
  • GFHW33115 HUBBELL HW GFCI, 30A 120/240V, AUTO, W/ENUN
  • GFHW33115 HUBBELL HW GFCI, 30A 120/240V, AUTO, W/ENUN

Description: Wiring Device-Kellems, GFHW33115, 4-Wire Automatic Multi-Strand Fabricated Hard Wired Gfci, 1-Phase Corrosion Resistant Grounding Male Standard Cord Mount, 28 VDC, 30 A, 7200 W Power, 60 Hz Frequency, -30 to 150 deg F, NEMA 4X Enclosure, Composite, Yellow, 24 in L Dimensions

Manufacturer PN: GFHW33115

UPC:  78358500531

Kendall Electric Inc PN: 4312114

Invoice Description:

GFHW33115 HUBBELL HW GFCI, 30A 120/240V, AUTO, W/ENUN


SPEC SHEET

▸ See All in Hard Wired GFCI

 

Wiring Device-Kellems GFHW33115 1-Phase Corrosion Resistant Grounding Male Standard Cord Mount 4-Wire Automatic Multi-Strand Fabricated Hard Wired Gfci, 28 VDC, 30 A, 7200 W Power Rating, NEMA 4X Enclosure, Composite

Log In for Pricing and Availability

Note: Lead times are estimates only

 
 

Description

Wiring Device-Kellems, GFHW33115, 4-Wire Automatic Multi-Strand Fabricated Hard Wired Gfci, 1-Phase Corrosion Resistant Grounding Male Standard Cord Mount, 28 VDC, 30 A, 7200 W Power, 60 Hz Frequency, -30 to 150 deg F, NEMA 4X Enclosure, Composite, Yellow, 24 in L Dimensions

Specifications

 Amperage Rating 30 A
 Application Industrial, Commercial and Wire into Circuit Applications
 Brand Name Hubbell Premise Wiring
 Color Yellow
 Dimensions 24 in L
 Enclosure NEMA 4X
 Frequency Rating 60 Hz
 Includes Foam Gasket, Mounting Template and Detailed Instructions
 Manufacturer Part Number GFHW33115
 Material Composite
 Power Rating 7200 W
 Standards/Approvals cULus Listed|UL 943
 Temperature Rating -30 to 150 deg F
 Type 1-Phase Corrosion Resistant Grounding Male Standard Cord Mount
 Voltage Rating 28 VDC

Features

▪ Trips if ground and neutral touch at load side
▪ Red blinking light plus optional audible alarm
▪ Open neutral protection Trips upon loss of neutral
▪ Automatically energizes or sets the GFCI for use once power is applied to the circuit
▪ After a ground fault condition, unit must be reset by pushing the reset button
▪ This feature eliminates the need for the unit to be reset each time the power is turned ON
▪ Automatic reset is ideal where temporary power failure is likely and undesirable such as waste water treatment plants, portable signs and some pump applications
▪ Offers a 4 to 6 mA trip level
▪ The alarm alerts you if a ground fault has occurred and the GFCI has tripped
▪ The alarm may be disabled or wired into a switch so that the customer has the choice of use or non-use
▪ Red light begins blinking when a ground fault is detected and the output power is interrupted
▪ Electromagnetic Latching Mechanism
 