Description: Bussmann Fusetron™ Fuse, Current Limiting Time Delay, Series: FRS-R, Indicating/Non-Indicating: Indicating, Rejection/Non-Rejection: Rejection, 30 A, 600 V AC/300 V DC, 200/20 kAIC Interrupt, Class: RK5, 10 s at 500% Response, Ferrule End Terminal, Holder Mount, Cylindrical Body Type, Dual Element, Fiberglass, 0.81 in Dia x 5 in L Body Size

Manufacturer PN: FRS-R-30ID

UPC:  05171220460

Kendall Electric Inc PN: 2655587

Invoice Description:

FRSR30ID BUS FUSE UL CLASS RK5 DUAL ELEMENT TIME DELAY (1)


SPEC SHEET

▸ See All in Time Delay Fuses

 

Bussmann Fusetron™ FRS-R-30ID Current Limiting Time Delay Fuse, 30 A, 600 V AC/300 V DC, 200/20 kAIC Interrupt, RK5 Class, Cylindrical Body

Log In for Pricing and Availability

 
 

Description

Bussmann's UL Class RK5 Fusetron product offering provides energy efficient advanced protection with its dual-element, time-delay construction and is available with optional open fuse indication on select ratings. Available in both 250Vac and 600Vac, 200kA RMS Sym interrupting rating and sizes ranging from 0 to 600 amp. Fusetron's deliver 10 seconds (minimum) of time-delay at 500 of rated current (8 seconds for 1/10-30A sizes).
Bussmann Fusetron™ Fuse, Current Limiting Time Delay, Series: FRS-R, Indicating/Non-Indicating: Indicating, Rejection/Non-Rejection: Rejection, 30 A, 600 V AC/300 V DC, 200/20 kAIC Interrupt, Class: RK5, 10 s at 500% Response, Ferrule End Terminal, Holder Mount, Cylindrical Body Type, Dual Element, Fiberglass, 0.81 in Dia x 5 in L Body Size

Specifications

 Amperage Rating 30 A
 Application Industrial Facilities and Factories, Safety and Security Systems, Combination Starters, Machinery Disconnects, Motor Control Centers and Power Panelboard Applications
 Body Size 0.81 in Dia x 5 in L
 Body Type Cylindrical
 Brand Name Bussmann
 Class RK5
 Element Dual
 Indicating Non Indicating Indicating
 Manufacturer Part Number FRS-R-30ID
 Material Fiberglass
 Mounting Type Holder
 Rejection Non Rejection Rejection
 Response Time 10 s at 500%
 Series FRS-R
 Standards/Approvals CE Marked
 Terminal Type Ferrule End
 Type Current Limiting Time Delay
 Video Links 
 Voltage Rating 600 V AC/300 V DC

Features

▪ Helps protect motors against burnout from 1 ph on 3 ph systems
▪ Simplifies and improves blackout prevention (selective co-ordination ratios)
▪ Dual element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short circuit and overload protection
▪ The overload element provides protection against low level overcurrent of overloads and will hold an overload which is 5X the amp rating of the fuse for a minimum of 10 s
▪ Permanent replacement fuse indication
▪ Provides motor overload, ground fault and short circuit protection
▪ When used in circuits subject to surge currents such as those caused by motors, transformers and other inductive components, these fuses can be sized close to full load amps to give maximum overcurrent protection
▪ Permits the use of smaller and less costly switches
▪ The time delay feature makes it possible to use fuse amp ratings which are much smaller than those of non-time delay fuses
▪ Considerable cost savings occur by permitting the use of smaller size switches, panels and fuses themselves
▪ Provides a higher degree of short circuit protection (greater current limitation) in circuits in which surge currents or temporary overloads occur
▪ Helps protect motors against burnout from overloads
▪ Gives motor running back-up protection to motors without extra costs
 