Description: Fluke® Power Logger, 3-Phase, 100 to 240 V, 19.8 x 16.7 x 9 cm Dimensions

Manufacturer PN: FLUKE-1736/B

UPC:  09596977252

Kendall Electric Inc PN: 3538185

Invoice Description:

FLUKE1736/B FLUKE POWER LOGGER 09596977252


SPEC SHEET

▸ See All in Power Meters

 

Fluke® FLUKE-1736/B 3-Phase Power Logger, 100 to 240 V

Log In for Pricing and Availability

Note: Lead times are estimates only

 
 

Description

3-Phase Power Loggers built with Fluke Connect mobile app and desktop software compatibility give you the data you need to make critical power quality and energy decisions in real-time. The ideal test tools for conducting energy studies and basic power quality logging, it automatically captures and logs over 500 power quality parameters so you have more visibility into the data you need to optimize system reliability and savings.
Fluke® Power Logger, 3-Phase, 100 to 240 V, 19.8 x 16.7 x 9 cm Dimensions

Specifications

 Brand Name Fluke
 Dimensions 19.8 x 16.7 x 9 cm
 Manufacturer Part Number FLUKE-1736/B
 Standards/Approvals ECCN: EAR99|PROP65: This product is in Compliant with PROP65; it is not known to contain any chemicals associated with this regulation
 Type 3-Phase
 Voltage Rating 100 to 240 V

Features

▪ Power: IEEE 1459
▪ Tamper protection: Kensington lock slot
▪ Harmonics: IEC 61000 to 4-7: Class 1
▪ Resolution: 16-bit synchronous sampling
▪ Relative humidity, operating: 15% to 85% non-condensing
▪ On-battery runtime: Four Hours in standard operating mode, upto 5.5 Hours in power saving mode
▪ Accuracy: /- 1%
▪ Operating altitude: 2000 m (up to 4000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV)
▪ Input voltage: Clamp input: 500 mVrms/50 mVrms; CF 2.8
▪ Coupling material: POM ABS/PC
▪ Triggered recordings: Full cycle RMS updated every half cycle of voltage and current (Urms1/2 according to IEC61000 to 4-30)
▪ Total harmonic distortion: Calculated on 50 harmonics
▪ Temperature coefficient over operating temperature range: 0.05% of reading/ Degrees C 0.09% of reading/ Degrees F
▪ Enclosure: IP50 in accordance with EN60529
▪ Averaging interval: 10 Minutes
▪ Mains power frequency: 50/60 Hz /-15%
▪ Input signal frequency: 50/60 Hz (42.5 to 69 Hz)
▪ Probe cable length: 305 mm (12 in)
▪ Maximum no-load consumption: < .3 W only when powered using IEC 60320 input
 