Page Loading...
Eaton
FAZ-D30/3-NA CH FAZ-NA UL 489 MCB 3P 30A D CURVE

Mouse over image to zoom, click to enlarge

  • FAZ-D30/3-NA CH FAZ-NA UL 489 MCB 3P 30A D CURVE
  • FAZ-D30/3-NA CH FAZ-NA UL 489 MCB 3P 30A D CURVE
  • FAZ-D30/3-NA CH FAZ-NA UL 489 MCB 3P 30A D CURVE
  • FAZ-D30/3-NA CH FAZ-NA UL 489 MCB 3P 30A D CURVE
  • FAZ-D30/3-NA CH FAZ-NA UL 489 MCB 3P 30A D CURVE

Description: EATON Miniature Circuit Breaker, Current Limiting, Series: FAZ-NA, 277/480 V AC, 30 A, 50/60 Hz Frequency, 10 to 14 kA Interrupt, Thermal Magnetic Trip, 10 to 20X Trip, 3 Pole, Toggle Actuator, Screw/Standard Terminal Connection, 18 to 6 AWG, 18 to 10 AWG Wire, DIN Rail Mounting, 40 deg C, 2.97 in W x 2.09 in D x 4.13 in H Dimensions

Manufacturer PN: FAZ-D30/3-NA

UPC:  01508102149

Kendall Electric Inc PN: 3613257

Invoice Description:

FAZ-D30/3-NA CH FAZ-NA UL 489 MCB 3P 30A D CURVE


SPEC SHEET
 

EATON FAZ-D30/3-NA Current Limiting Miniature Circuit Breaker, 277/480 V AC, 30 A, 10 to 14 kA Interrupt, 3 Poles, Thermal Magnetic Trip

Log In for Pricing and Availability

 
 

Description

Eaton's FAZ, dual rated UL and IEC circuit breakers are ideal for providing protection in many applications. A current limiting design provides fast short-circuit interruption, offering superior protection by reducing peak let-through current. Superior product quality, tested reliability and safety make Eaton’s UL 1053 Residual Current Circuit Breaker (RCCB) the optimum product for residual current applications. The UL 1053 RCCB circuit breakers provide safety and protection for personnel and equipment.
EATON Miniature Circuit Breaker, Current Limiting, Series: FAZ-NA, 277/480 V AC, 30 A, 50/60 Hz Frequency, 10 to 14 kA Interrupt, Thermal Magnetic Trip, 10 to 20X Trip, 3 Pole, Toggle Actuator, Screw/Standard Terminal Connection, 18 to 6 AWG, 18 to 10 AWG Wire, DIN Rail Mounting, 40 deg C, 2.97 in W x 2.09 in D x 4.13 in H Dimensions

Specifications

 Actuator Type Toggle
 Amperage Rating 30 A
 Application Branch Circuit Device, Circuit Protection, Convenience Receptacle Circuits, Motor Control Circuits, HACR Internal/External Equipment, PLC I/O Points, Computers, Power Supplies, Control Instrumentation, Relays, UPS, Power Conditioners, Conventional Energy, Renewable Energy and Alternative Energy Generation, Datacenters, IT Space - CI, Hyper Converged, Marine Vessels and Equipment and Industrial Applications
 Brand Name EATON
 Connection Type Screw/Standard Terminal
 Dimensions 2.97 in W x 2.09 in D x 4.13 in H
 Frequency Rating 50/60 Hz
 Manufacturer Part Number FAZ-D30/3-NA
 Mounting Type DIN Rail
 Number of Poles 3
 PART NUMBER KEYWORDS FAZ-D30/3-NA ; FAZD303NA ; 11231950 ; 04015081021499 ; 4015081021499
 Series FAZ-NA
 Standards/Approvals UL 489,CSA Std. C22.2 No. 235
 Temperature Rating 40 deg C
 Trip Range 10 to 20X
 Type Current Limiting
 Voltage Rating 277/480 V AC

Features

▪ Current limiting design provides fast short-circuit interruption that reduces the let-through energy, which can damage the circuit
▪ Suitable for branch circuit device protection
▪ Thermal magnetic over current protection
▪ Three levels of short circuit protection, categorized by B, C and D curves
▪ Trip-free design breaker can not be defeated by holding the handle in the On position
▪ Captive screws cannot be lost
▪ Field installable shunt trip and auxiliary switch subsequent mounting
▪ Contact position indicator (red/green)
▪ Possibility for sealing the toggle in "On/Off" position
 
Time Zone 
 
 
 

Recently Viewed Products: