EZM1800CB SQD METERING EZM MAIN

Mouse over image to zoom, click to enlarge

Description: Square D™ EZ Meter-Pak™ Meter Center Main Unit, Circuit Breaker, Series: EZM, 120/240 VAC, 800 A, 1 ph, NEMA 3R Enclosure, 53.97 in H x 18.66 in W x 11.5 in D Dimensions

Manufacturer PN: EZM1800CB

UPC:  78590130465

Kendall Electric Inc PN: 3961701

Invoice Description:

EZM1800CB SQD METERING EZM MAIN


SPEC SHEET

▸ See All in Meter Mains

 

Square D™ EZ Meter-Pak™ EZM1800CB Circuit Breaker Meter Center Main Unit, 120/240 VAC, 800 A, 1 Phase

Log In for Pricing and Availability

Note: Lead times are estimates only

 
 

Schneider Electric and Square D products are only sold to customers in our authorized sales territory. Please log into your account to see locally available product.

Description

Square D™ EZ Meter-Pak™ centers are available from 1 to 6 H meter breaker units. Greater selectivity means faster, easier installations. Plug-on QO™ 2-pole circuit breakers are used in 125 A units, while 200 A residential units use factory installed Q2 2-pole circuit breakers.
Square D™ EZ Meter-Pak™ Meter Center Main Unit, Circuit Breaker, Series: EZM, 120/240 VAC, 800 A, 1 ph, NEMA 3R Enclosure, 53.97 in H x 18.66 in W x 11.5 in D Dimensions

Specifications

 Amperage Rating 800 A
 Application Service Entrance Equipment Applications
 Brand Name Square D
 Dimensions 53.97 in H x 18.66 in W x 11.5 in D
 Enclosure NEMA 3R
 Manufacturer Part Number EZM1800CB
 Phase 1
 Series EZM
 Standards/Approvals UL File No. E10582/E131840|NEC Certified|PROP65: Cancer and Reproductive Harm - www.p65warnings.ca.gov
 Type Circuit Breaker
 Voltage Rating 120/240 VAC

Features

▪ Top and bottom wiring gutters with knockouts allow branch circuits to exit from either the top, bottom or back of the unit
▪ Meter breaker units can be supplied with either 1-phase 3-wire or 3-phases 4-wire service
▪ The main bus on residential units with 40 to 200 a circuit breaker provisions is 800 or 1200 a in units using commercial 200 and 400 A branch circuit breakers
▪ To suit individual applications, residential and commercial devices may be interconnected
▪ Basic devices for connection to 3-phases 4-wire 120/208 VAC service are factory phase balanced to save installation time
▪ The phase balancing may be modified in the field to meet most system variations
▪ Lugs 3 cables 3/0 AWG to 500 kcmil Al/Cu line, lugs 3 cables 3/0 AWG to 500 kcmil Al/Cu neutral, lugs 1 cable 6 AWG to 300 kcmil Al/Cu ground electrical connection
▪ Steel enclosure material
▪ Aluminum busbar
 