EYF75 APP 3/4 SEAL UNILET..

Mouse over image to zoom, click to enlarge

Description: Appleton® UNILETS® Conduit Sealing Fitting, Dust-Ignitionproof Explosionproof Raintight, Series: EY Series, 3/4 in, For Use With: IMC/Threaded Rigid Metallic Conduit, Malleable Iron, Triple Coated, 3.5 in L x 1.38 in W

Manufacturer PN: EYF-75

UPC:  78138113512

Kendall Electric Inc PN: 16811

Invoice Description:

EYF75 APP 3/4 SEAL UNILET..


SPEC SHEET

▸ See All in Explosionproof Conduit Sealing Fittings

 

Appleton® UNILETS® EYF-75 Dust-Ignitionproof Explosionproof Raintight Conduit Sealing Fitting, 3/4 in, For Use With IMC/Threaded Rigid Metallic Conduit, Malleable Iron, Triple Coated

Log In for Pricing and Availability

 
 

Description

Appleton® UNILETS® Conduit Sealing Fitting, Dust-Ignitionproof Explosionproof Raintight, Series: EY Series, 3/4 in, For Use With: IMC/Threaded Rigid Metallic Conduit, Malleable Iron, Triple Coated, 3.5 in L x 1.38 in W

Specifications

 Application For prevent passage of gases, vapors or flames from one portion of conduit system to another
 Brand Name Appleton
 Dimensions 3.5 in L x 1.38 in W
 Finish Triple Coated
 Manufacturer Part Number EYF-75
 Material Malleable Iron
 Series EY Series
 Size 3/4 in
 Standards/Approvals UL 886|UL 1203 File No. E10444|CSA C22.2 No. 30|CSA 065181|Class I, Groups A, B, C, D|Class II, Groups E, F, G|Class III
 Suitable For Use With IMC/Threaded Rigid Metallic Conduit
 Type Dust-Ignitionproof Explosionproof Raintight

Features

▪ 25% fill vertical and horizontal conduit sealing fittings for close turning radius
▪ Chromate/epoxy powder coated/zinc electroplated finish
▪ Smooth, rounded integral bushing in each hub to protect conductor insulation
▪ Accurately tapped, tapered NPT threads for tight, rigid joints and ground continuity
▪ Removable nipple in male sealing fitting may be used interchangeably in top or bottom hub
▪ Restrict any explosion to the sealed off enclosure
▪ Required in Class I, Division 1 and 2 locations within 18 in of enclosures containing apparatus that may cause arcs, sparks or high temperatures
▪ Required in Class I, Division 1 and 2 locations where 2 in or larger conduit enters enclosure, fitting housing terminals, splices or taps
▪ Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location
▪ Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 in or less conduit, seal must be located within 18 in of either enclosure
▪ Required where cables which exceed rate of gas or vapor transmission permitted for seals are used in Class I, Division 2 locations
 