Page Loading...
Eaton
DS7-340SX200N0-N CH 2PH CONTROL RVSS W/ 24V AC/DC CONTROL

Mouse over image to zoom, click to enlarge

  • DS7-340SX200N0-N CH 2PH CONTROL RVSS W/ 24V AC/DC CONTROL
  • DS7-340SX200N0-N CH 2PH CONTROL RVSS W/ 24V AC/DC CONTROL

Description: EATON Soft Start Controller, Reduced Voltage Standard, Series: DS7, 480 V AC, 200 A, 50/60 Hz Frequency, 150 hp Motor, 24 VAC/VDC Coil, 1 to 30 s, 0 to 30 s Timing, 3 ph, Start/Stop Action, Solid-State Overload Relay, IP20 Enclosure, Starting Modes: Current Limit/Ramp, 0 to 40 deg C Operating, 8.46 in H x 4.25 in W x 7.01 in D Dimensions

Manufacturer PN: DS7-340SX200N0-N

UPC:  78668588383

Kendall Electric Inc PN: 4875506

Invoice Description:

DS7-340SX200N0-N CH 2PH CONTROL RVSS W/ 24V AC/DC CONTROL


SPEC SHEET

▸ See All in Open Soft Starters

 

EATON DS7-340SX200N0-N Reduced Voltage Standard Soft Start Controller With Internal Bypass, 24 VAC/VDC V Coil, Start/Stop Action, IP20 Enclosure

Log In for Pricing and Availability

Note: Lead times are estimates only

 
 

Description

DS7 easily fits in place of existing soft starters, wye-delta starters or across-the-line NEMA and IEC starters. The voltage ramp start method provides a voltage ramp to the motor for constant torque increase. Users set initial voltage values and the duration of the ramp to full voltage conditions. Soft Stop allows for a controlled stopping of load when a stop-time greater than the coast-to-stop time is desired; for high friction loads where a sudden stop may cause system damage.
EATON Soft Start Controller, Reduced Voltage Standard, Series: DS7, 480 V AC, 200 A, 50/60 Hz Frequency, 150 hp Motor, 24 VAC/VDC Coil, 1 to 30 s, 0 to 30 s Timing, 3 ph, Start/Stop Action, Solid-State Overload Relay, IP20 Enclosure, Starting Modes: Current Limit/Ramp, 0 to 40 deg C Operating, 8.46 in H x 4.25 in W x 7.01 in D Dimensions

Specifications

 Amperage Rating 200 A
 Application Electrical Assemblies, Panels and OEMs Applications
 Brand Name EATON
 Coil Voltage 24 V AC/DC
 Dimensions 8.46 in H x 4.25 in W x 7.01 in D
 Enclosure IP20
 Frequency Rating 50/60 Hz
 Manufacturer Part Number DS7-340SX200N0-N
 Motor Power 150 hp
 Operating Temperature 0 to 40 deg C
 Overload Relay Solid-State
 Phase 3
 Series DS7
 Standards/Approvals CSA Certified,UL Listed,IEC 60947-4-2,EN 60947-4-2,C-Tick Compliant,CE Marked
 Starting Modes Current Limit/Ramp
 Timing 1 to 30 s, 0 to 30 s
 Type Reduced Voltage Standard
 Video Links 
 Voltage Rating 480 V AC

Features

▪ Auxiliary relays indicate status of the soft start controllers
▪ 24 VAC/VDC control voltage enhances personnel and equipment safety
▪ 150 hp at 480 VAC
▪ Run bypass mode greatly reduces internal heating created by the power dissipation across the SCRs
▪ The bypass relay directly connects the motor to the line and improves system efficiency by reducing internal power losses
▪ Less heat minimizes enclosure size and cooling requirements and maximizes the life of all devices in the enclosure
▪ LED displays device status and provides fault indication
▪ Variable ramp times and voltage control (torque control) settings provide unlimited starting configurations, allowing for maximum application flexibility
▪ Soft stop control suits applications where an abrupt stop of the load is not acceptable
▪ Soft acceleration and deceleration reduces wear on belts, gears, chains, clutches, shafts and bearings
▪ Minimizes the peak inrush current's stress on the power system
▪ Peak starting torque can be managed to diminish mechanical system wear and damage
 
Time Zone 
 
 
 

Recently Viewed Products: