Description: EATON Digital Display Unit, LCD Display, 5 in L x 3-3/4 in W x 3-3/4 in H Dimensions

Manufacturer PN: D64D1

UPC:  78211489510

Kendall Electric Inc PN: 3622651

Invoice Description:

D64D1 CH DIGITAL DISPLAY UNIT FOR D64RPB100


SPEC SHEET

▸ See All in Programmable Relay Display Module

 

EATON D64D1 Digital Display Unit, LCD Display

Log In for Pricing and Availability

Note: Lead times are estimates only

 
 

Description

Eaton’s D65 series phase monitoring relays prevent motors from running at temperatures above approved ratings. The devices provide protection against phase loss, phase reversal, and phase unbalance due to blown fuses, broken wires or worn contacts. They monitor simultaneous voltage drops/increases and help to prevent damaged machinery and the injury of personnel.
EATON Digital Display Unit, LCD Display, 5 in L x 3-3/4 in W x 3-3/4 in H Dimensions

Specifications

 Application Automation and Logic Control Equipment Applications
 Brand Name EATON
 Dimensions 5 in L x 3-3/4 in W x 3-3/4 in H
 Manufacturer Part Number D64D1
 Standards/Approvals UL Listed,CSA Certified

Features

▪ When a 5000:5 ratio interposing CT is used, all displayed values are to be interpreted as kA rather than amps
▪ Used with 30 ft of standard 4-wire telephone type cable connection
▪ Use with D64RPB100 Series B1 digital ground fault relay
▪ Continuous reading of actual ground fault current, employing auto ranging
▪ Display of the pre-trip ground fault current, after a trip has occurred (flashing display)
▪ Display of the trip current setting, after a test trip has been activated
▪ Test and RESET pushbuttons
▪ The RESET button must be held pressed before the test is pressed to invoke the test procedure
▪ The function of this button can be enabled/disabled by inserting the interconnecting cable from the D64RPB100 relay into one of two sockets, TEST on or TEST off, on the right side of the display
▪ Pushing verify pushbutton shows if D64RPB100 tripped due to a ground fault prior to loss of its control voltage red trip LED lights or if there was no ground fault green run LED light strip-green run LED lights
▪ This indication will remain available for at least ten hours
▪ The numerical LCD window displays actual ground fault current in amps