Description: EATON Meter Breaker Socket, Type CH 7-Jaw 1-Socket 4-Wire Safety Unmetered, 277/480 V AC, 200 A, 3 ph, Bottom/Underground Feed, 7 Jaws, 6 AWG to 250 kcmil Wire, Ring Cover, Load Terminal, Surface Mount, NEMA 3R, 6.06 in L x 22.3 in W x 30.06 in H

Manufacturer PN: CHU227MTBLB

UPC:  78211616499

Kendall Electric Inc PN: 3873398

Invoice Description:

CHU227MTBLB CH 200A, SAFETY SOCKET 7 JAW, UG WITH PROVISION FOR 200A BREAKE


SPEC SHEET

▸ See All in Meter Socket Circuit Breaker Combination

 

EATON CHU227MTBLB Type CH 7-Jaw 1-Socket 4-Wire Safety Unmetered Meter Breaker Socket With Provision for Main Circuit Breaker, 277/480 V AC, 200 A, 3 Phase , NEMA 3R Enclosure

Log In for Pricing and Availability

Note: Lead times are estimates only

 
 

Description

Eaton's temporary power panels provide safe, reliable power for RV and construction sites. Durable, long-lasting units are available as metered (ring or ringless) or unmetered and can be mounted at the surface, on a pedestal, or in a back-to-back configuration.
EATON Meter Breaker Socket, Type CH 7-Jaw 1-Socket 4-Wire Safety Unmetered, 277/480 V AC, 200 A, 3 ph, Bottom/Underground Feed, 7 Jaws, 6 AWG to 250 kcmil Wire, Ring Cover, Load Terminal, Surface Mount, NEMA 3R, 6.06 in L x 22.3 in W x 30.06 in H

Specifications

 Amperage Rating 200 A
 Application Power Distribution, Commercial, Electrical Assemblies, Panels, OEMs and Indoor/Outdoor Applications
 Brand Name EATON
 Cover Type Ring
 Dimensions 6.06 in L x 22.3 in W x 30.06 in H
 Enclosure NEMA 3R
 Feed Type Bottom/Underground
 Manufacturer Part Number CHU227MTBLB
 Mounting Type Surface
 Number of Jaws 7
 Phase 3
 Standards/Approvals UL Listed
 Terminal Type Load
 Type Type CH 7-Jaw 1-Socket 4-Wire Safety Unmetered
 Voltage Rating 277/480 V AC

Features

▪ Larger 250 kcmil lugs and additional knockouts for ease of installation
▪ Factory installed neutral assemblies
▪ Hub provisions on top endwall
▪ Ring type sockets are provided with a sealing ring
▪ Padlockable device covers provide an additional measure of security and help prevent tampering
▪ Most units have center keyhole for easy one person installation
▪ Without distribution section
 