CHF230 CH CIRCUIT BREAKER 2P 30 AMP 120/240V..

Mouse over image to zoom, click to enlarge

Description: EATON Circuit Breaker, Type CHF Standard, 120/240 VAC, 30 A, 10 kA Interrupt, Common/Flag Trip, 2 Pole, 1 ph, Toggle Handle Actuator, Box Lug, (1) 14 to 8 AWG, (2) 14 to 10 AWG Copper/Aluminum Wire, Plug-On Mount, 60 to 75 deg C, 3 in L x 3/4 in W x 3 in H

Manufacturer PN: CHF230

UPC:  78668536190

Kendall Electric Inc PN: 2838550

Invoice Description:

CHF230 CH CIRCUIT BREAKER 2P 30 AMP 120/240V..


SPEC SHEET

▸ See All in Std Thermal Magnetic Circuit Breakers

 

EATON CHF230 Type CHF Standard Circuit Breaker With Mechanical Trip Flag, 120/240 VAC, 30 A, 10 kA Interrupt, 2 Poles, Common/Flag Trip

Log In for Pricing and Availability

 
 

Description

Eaton's residential CH circuit breakers provide premium overload protection. The Type CH circuit breakers trip to the OFF position, eliminating nuisance callbacks. The CHF family also includes a trip flag to differentiate between a trip and the breaker being turned off. The thermal-magnetic trip curve avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions. Multiple breakers have an internal common trip connection to operate all poles simultaneously. Handles are marked with ON-OFF indication and ampere rating of the breaker.
EATON Circuit Breaker, Type CHF Standard, 120/240 VAC, 30 A, 10 kA Interrupt, Common/Flag Trip, 2 Pole, 1 ph, Toggle Handle Actuator, Box Lug, (1) 14 to 8 AWG, (2) 14 to 10 AWG Copper/Aluminum Wire, Plug-On Mount, 60 to 75 deg C, 3 in L x 3/4 in W x 3 in H

Specifications

 Actuator Type Toggle Handle
 Amperage Rating 30 A
 Application Circuit Protection, Residential Type CH Load Centers and Meter Breaker Panels, Light Commercial Distribution Panels, Pool Panels, Residential Transfer Switch Panels and Various OEM Applications
 Brand Name EATON
 Connection Type Box Lug
 Dimensions 3 in L x 3/4 in W x 3 in H
 Manufacturer Part Number CHF230
 Mounting Type Plug-On
 Number of Poles 2
 Phase 1
 Standards/Approvals UL 489|CSA C22.2 No 5
 Temperature Rating 60 to 75 deg C
 Type Type CHF Standard
 Voltage Rating 120/240 VAC

Features

▪ One 14 to 8 AWG, (2) 14 to 10 AWG copper aluminum at 60 to 75 deg C wire
▪ Easy to install
▪ Easy to reset
▪ Best in class performance
▪ Circuit breaker is clearly marked identifying amperage, ratings and the brand
▪ Trip flag visibly indicates breaker status
▪ 3/4 in per pole
 
Time Zone 
 
 
 