CH4L125SP CH 8 CIRCUIT ML SURF MOUNT 1P 125 AMP NEMA 1 LOADCENTER

Mouse over image to zoom, click to enlarge

Description: EATON Main Lug Loadcenter, 1-Phase Standard, 120/208Y/240 VAC, 125 A, 8 Pole, 25 kA Interrupt, 4 Circuits, CH Breaker, 3-Wire Wiring Configuration, 4 Spaces, 14 to 1/0 AWG Wire, Surface Mount, NEMA 1, NEMA 7 Enclosure Box, Metal Housing, 13 in L x 11 in W x 3.69 in H

Manufacturer PN: CH4L125SP

UPC:  78211419050

Kendall Electric Inc PN: 2016427

Invoice Description:

CH4L125SP CH 8 CIRCUIT ML SURF MOUNT 1P 125 AMP NEMA 1 LOADCENTER


SPEC SHEET

▸ See All in Single Phase Main Lug Load Centers

 

EATON CH4L125SP 1-Phase Standard Main Lug Loadcenter, 120/208Y/240 VAC, 125 A, 8 Poles, 25 kA Interrupt

Log In for Pricing and Availability

 
 

Description

Eaton's CH 3/4-inch loadcenters enclose CH circuit breakers for power distribution and circuit protection in residential and light commercial applications. Also called a breaker box, electrical box or even a fuse box, the main function is to take electricity supplied by the utility and distribute it throughout the home to feed lights and receptacles. Covers are typically packaged separately and available as surface or flush mount.
EATON Main Lug Loadcenter, 1-Phase Standard, 120/208Y/240 VAC, 125 A, 8 Pole, 25 kA Interrupt, 4 Circuits, CH Breaker, 3-Wire Wiring Configuration, 4 Spaces, 14 to 1/0 AWG Wire, Surface Mount, NEMA 1, NEMA 7 Enclosure Box, Metal Housing, 13 in L x 11 in W x 3.69 in H

Specifications

 Amperage Rating 125 A
 Application Electrical Assemblies, Panels and OEMs Applications
 Brand Name EATON
 Breaker Type CH
 Dimensions 13 in L x 11 in W x 3.69 in H
 Enclosure NEMA 1
 Enclosure Box Size NEMA 7
 Housing Material Metal
 Manufacturer Part Number CH4L125SP
 Mounting Type Surface
 Number of Circuits 4
 Number of Poles 8
 Number of Spaces 4
 Standards/Approvals UL 50/67|PROP65: This product can expose you to chemicals including: Nickel compounds which is known to the State of California to cause cancer and Bisphenol A (BPA) which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
 Type 1-Phase Standard
 Video Links 
 Voltage Rating 120/208Y/240 VAC
 Wiring Configuration 3-Wire

Features

▪ Copper bus material
▪ Overhead or underground feed
▪ Single-phase
▪ Ground bar kits priced separately
▪ For 2/4 and 6/12 circuit load centers, use type GBK5 or GBK520 ground bar
▪ Ground bars mount to the left side wall of the enclosure for the 4/8, 6/12 and 8/16 circuit load centers
▪ Suitable for use as service equipment when not more than two service disconnecting mains are provided
▪ Insulated/bondable split neutral type
▪ 3/4 in pole
 