Page Loading...
Eaton
CCP2-1-60CF BUSSMANN CCP2 1P 60A CF

Mouse over image to zoom, click to enlarge

Description: EATON Bussmann Circuit Protector Disconnect Switch, Compact Fused, 347 V AC/125 V DC, 60 A, 1 Pole, 35 mm DIN Rail Mount, Switch Handle Operator, -4 to 167 deg F Operating, 3 in W, 8.1 in Height

Manufacturer PN: CCP2-1-60CF

UPC:  05171270927

Kendall Electric Inc PN: 4325482

Invoice Description:

CCP2-1-60CF BUSSMANN CCP2 1P 60A CF


SPEC SHEET
 

EATON Bussmann CCP2-1-60CF Compact Fused Circuit Protector Disconnect Switch, 347 V AC/125 V DC, 60 A, 1 Poles

Log In for Pricing and Availability

Note: Lead times are estimates only

 
 

Description

The revolutionary Bussmann™ series CCP with CUBEFuse™ is a fused branch circuit disconnect that requires up to 67% less space with ratings up to 600A. The CCP with CUBEFuse simplifies selective coordination and allows for isolation of individual branch circuit loads for safe work practices.
EATON Bussmann Circuit Protector Disconnect Switch, Compact Fused, 347 V AC/125 V DC, 60 A, 1 Pole, 35 mm DIN Rail Mount, Switch Handle Operator, -4 to 167 deg F Operating, 3 in W, 8.1 in Height

Specifications

 Amperage Rating 60 A
 Brand Name EATON
 Height 8.1 in
 Manufacturer Part Number CCP2-1-60CF
 Mounting Type 35 mm DIN Rail
 Number of Poles 1
 Operating Temperature -4 to 167 deg F
 Operator Switch Handle
 PART NUMBER KEYWORDS CCP2-1-60CF ; CCP2160CF ; 14758446 ; 051712709279 ; 51712709279 ; 05171270927 ; 00051712709279
 Standards/Approvals UL 98 File No. E302370, Guide WHTY|cULus to Canadian Standard 22.2 No. 4-04 File No. E302370, Guide WHTY7|CE Certified|CCC Certified
 Type Compact Fused
 Voltage Rating 347 V AC/125 V DC
 Width 3 in

Features

▪ Padlockable for lockout/tagout procedures with a 1/4 in lock
▪ 200 kA AC, 100 kA DC short circuit current rating
▪ Uses UL class CF time delay or fast acting CUBEFuse™ with class J electrical performance
▪ Extremely compact design at 25.4 mm wide per pole
▪ Amp rating rejection disconnects will not accept a CUBEFuse™ amp rating greater than switch rating
▪ Disconnect rated to provide a means for load isolation
▪ UL 98 listed and suitable for branch circuit disconnect and branch circuit protection with installed fuses
▪ Open fuse indication - local open fuse indication light standard on each pole
▪ Additional open fuse indication can be provided by the indicating time delay CUBEFuse™ (6 to 100 A)
▪ Finger-safe construction with 10 AWG wire or larger
▪ Built-in switch interlock prohibits removing or installing the fuse while in the ON position

Resources

 Product Data Sheet 
 
Time Zone 
 
 
 