Page Loading...
Eaton
BR816L125FDP C-H Main Lug Loadcenter

Mouse over image to zoom, click to enlarge

  • BR816L125FDP C-H Main Lug Loadcenter
  • BR816L125FDP C-H Main Lug Loadcenter
  • BR816L125FDP C-H Main Lug Loadcenter

Description: EATON Main Lug Loadcenter, 1-Phase Split, 120/240 V AC, 125 A, 16 Pole, 10 kA Interrupt, 16 Circuits, BR Breaker, 3-Wire Wiring Configuration, 8 Spaces, 14 to 1 AWG Cu/Al Wire, Flush Mount, NEMA 1, NEMA 7 Enclosure Box, 3.56 in L x 11 in W x 13 in H

Manufacturer PN: BR816L125FDP

UPC:  78667600143

Kendall Electric Inc PN: 2426363

Invoice Description:

BR816L125FDP C-H Main Lug Loadcenter


SPEC SHEET

▸ See All in Single Phase Main Lug Load Centers

 

EATON BR816L125FDP 1-Phase Split Main Lug Loadcenter, 120/240 V AC, 125 A, 16 Poles, 10 kA Interrupt

Log In for Pricing and Availability

Note: Lead times are estimates only

 
 

Description

Specially designed for easy installation, Eaton's BR 1-inch load centers house the branch circuit breakers and the wiring required to distribute power to individual circuits. They serve as main breaker for service entrances or as main lug when adding circuits to existing service. The main breaker protects the entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets.
EATON Main Lug Loadcenter, 1-Phase Split, 120/240 V AC, 125 A, 16 Pole, 10 kA Interrupt, 16 Circuits, BR Breaker, 3-Wire Wiring Configuration, 8 Spaces, 14 to 1 AWG Cu/Al Wire, Flush Mount, NEMA 1, NEMA 7 Enclosure Box, 3.56 in L x 11 in W x 13 in H

Specifications

 Amperage Rating 125 A
 Application Electrical Assemblies, Panels and OEMs Applications
 Brand Name EATON
 Breaker Type BR
 Dimensions 3.56 in L x 11 in W x 13 in H
 Enclosure NEMA 1
 Enclosure Box Size NEMA 7
 Includes Cover
 Manufacturer Part Number BR816L125FDP
 Mounting Type Flush
 Number of Circuits 16
 Number of Poles 16
 Number of Spaces 8
 Standards/Approvals UL 50/67|UL E52977|UL E8741
 Type 1-Phase Split
 Voltage Rating 120/240 V AC
 Wiring Configuration 3-Wire

Features

▪ Dual grounds, current design
▪ Twin neutral design located in wireway, away from circuit breakers, means easier wiring and balancing of the load
▪ Extra 1-1/2 in knockout for bundling allows maximum wiring gutter space for ease of wiring in compliance with NEC requirements
▪ 1-piece roll formed metal backpan with circuit breaker alignment notches ensures accurately aligned breaker and bus tabs
▪ Standard 14-3/8 in W enclosures fit snugly between wall studs
▪ Tangential main knockout eliminates the need for conduit offsets which permits faster, easier installation
▪ BR load centers feature Robertson slotted square combo screw heads, which means only one screwdriver is need for installation
▪ Indoor enclosure
▪ Copper aluminum wire at 60 to 75 deg C for main lugs
▪ Standard tin plated aluminum bus for excellent conductivity and corrosion-resistance
 
Time Zone 
 
 
 