Page Loading...
Eaton
BR612L125SP CH 12 CIRCUIT ML 1P 125 AMP NEMA 1 LOADCENTER

Mouse over image to zoom, click to enlarge

Description: EATON Main Lug Loadcenter, 1-Phase Split, 120/240 V AC, 125 A, 12 Pole, 10 kA Interrupt, 12 Circuits, BR Breaker, 3-Wire Wiring Configuration, 6 Spaces, 14 to 1 AWG Al/Cu Wire, Surface Mounting, NEMA 1 Enclosure, NEMA 7 Enclosure Box, 3.56 in L x 11 in W x 13 in D Dimensions

Manufacturer PN: BR612L125SP

UPC:  78667600203

Kendall Electric Inc PN: 2243758

Invoice Description:

BR612L125SP CH 12 CIRCUIT ML 1P 125 AMP NEMA 1 LOADCENTER


SPEC SHEET

▸ See All in Single Phase Main Lug Load Centers

 

EATON BR612L125SP 1-Phase Split Main Lug Loadcenter, 120/240 V AC, 125 A, 12 Poles, 10 kA Interrupt

Log In for Pricing and Availability

 
 

Description

Specially designed for easy installation, Eaton's BR 1-inch load centers house the branch circuit breakers and the wiring required to distribute power to individual circuits. They serve as main breaker for service entrances or as main lug when adding circuits to existing service. The main breaker protects the entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets.
EATON Main Lug Loadcenter, 1-Phase Split, 120/240 V AC, 125 A, 12 Pole, 10 kA Interrupt, 12 Circuits, BR Breaker, 3-Wire Wiring Configuration, 6 Spaces, 14 to 1 AWG Al/Cu Wire, Surface Mounting, NEMA 1 Enclosure, NEMA 7 Enclosure Box, 3.56 in L x 11 in W x 13 in D Dimensions

Specifications

 Amperage Rating 125 A
 Application Power Distribution Applications
 Brand Name EATON
 Breaker Type BR
 Dimensions 3.56 in L x 11 in W x 13 in D
 Enclosure NEMA 1
 Enclosure Box Size NEMA 7
 Manufacturer Part Number BR612L125SP
 Mounting Type Surface
 Number of Circuits 12
 Number of Poles 12
 Number of Spaces 6
 PART NUMBER KEYWORDS BR612L125SP ; 7431538 ; 786676002035 ; 78667600203 ; 00786676002035
 Standards/Approvals UL 67,UL 50
 Type 1-Phase Split
 Voltage Rating 120/240 V AC
 Wiring Configuration 3-Wire

Features

▪ Standard tin plated aluminum bus for excellent conductivity and corrosion-resistance
▪ Current design
▪ Twin neutral design located in wire way, away from circuit breakers, means easier wiring and balancing of the load
▪ Extra 1-1/2 in knockout for bundling allows maximum wiring gutter space for ease of wiring in compliance with NEC requirements
▪ 1-piece roll formed metal backpan with circuit breaker alignment notches ensures accurately aligned breaker and bus tabs
▪ Standard 14-3/8 in W enclosures fit snugly between wall studs
▪ Tangential main knockout eliminates the need for conduit offsets which permits faster, easier installation
▪ BR load centers feature Robertson® slotted square combo screw heads, which means only one screwdriver is need for installation
▪ Without cover
▪ Indoor enclosure
▪ Al/Cu wire at 60 to 75 deg C for main lugs
 
Time Zone