Page Loading...
Eaton
BR24L70SP CH 4 CIRCUIT ML 1P 70 AMP NEMA 1 LOADCENTER

Mouse over image to zoom, click to enlarge

Description: EATON Main Lug Loadcenter, 1-Phase, 120/240 VAC, 70 A, 4 Pole, 10 kA Interrupt, 4 Circuits, BR Breaker, 3-Wire Wiring Configuration, 2 Spaces, #8 to 2 AWG Wire, Surface Mount, NEMA 1, NEMA 5 Enclosure Box, Metal Housing, 3.88 in L x 14.31 in W x 23 in H

Manufacturer PN: BR24L70SP

UPC:  78667600167

Kendall Electric Inc PN: 2243757

Invoice Description:

BR24L70SP CH 4 CIRCUIT ML 1P 70 AMP NEMA 1 LOADCENTER


SPEC SHEET

▸ See All in Single Phase Main Breaker Load Centers

 

EATON BR24L70SP 1-Phase Main Lug Loadcenter, 120/240 VAC, 70 A, 4 Poles, 10 kA Interrupt

Log In for Pricing and Availability

 
 

Description

Specially designed for easy installation, Eaton's BR 1-inch load centers house the branch circuit breakers and the wiring required to distribute power to individual circuits. They serve as main breaker for service entrances or as main lug when adding circuits to existing service. The main breaker protects the entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets.
EATON Main Lug Loadcenter, 1-Phase, 120/240 VAC, 70 A, 4 Pole, 10 kA Interrupt, 4 Circuits, BR Breaker, 3-Wire Wiring Configuration, 2 Spaces, #8 to 2 AWG Wire, Surface Mount, NEMA 1, NEMA 5 Enclosure Box, Metal Housing, 3.88 in L x 14.31 in W x 23 in H

Specifications

 Amperage Rating 70 A
 Application Electrical Assemblies, Panels and OEMs Applications
 Brand Name EATON
 Breaker Type BR
 Dimensions 3.88 in L x 14.31 in W x 23 in H
 Enclosure NEMA 1
 Enclosure Box Size NEMA 5
 Housing Material Metal
 Manufacturer Part Number BR24L70SP
 Mounting Type Surface
 Number of Circuits 4
 Number of Poles 4
 Number of Spaces 2
 Standards/Approvals UL 50/67|PROP65: This product can expose you to chemicals including: Nickel compounds which is known to the State of California to cause cancer and Bisphenol A (BPA) which is known to the State of California to cause birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov
 Type 1-Phase
 Voltage Rating 120/240 VAC
 Wiring Configuration 3-Wire

Features

▪ 1 in maximum space
▪ Cover not included
▪ Current design
▪ Aluminum bus material
▪ Single-phase
▪ Used with type BR 1 in breakers
▪ Ground bar kits priced separately
▪ For 2/4 circuit load centers, use GBK5 or GBK520 ground bar
▪ Ground bars mount to the left side wall of the enclosure for the 4/8, 6/12 and 8/16 circuit load centers
▪ Suitable for use as service equipment when not more than six service disconnecting mains are provided
▪ Insulated/bondable split neutral type
 
Time Zone 
 
 
 

Recently Viewed Products: