Eaton
3MCB1600RBC-600 CH 1600A METERING MCB, 3 PH, WITH LUG LANDING TO ACCEPT 2-600 M

Mouse over image to zoom, click to enlarge

  • 3MCB1600RBC-600 CH 1600A METERING MCB, 3 PH, WITH LUG LANDING TO ACCEPT 2-600 M
  • 3MCB1600RBC-600 CH 1600A METERING MCB, 3 PH, WITH LUG LANDING TO ACCEPT 2-600 M
  • 3MCB1600RBC-600 CH 1600A METERING MCB, 3 PH, WITH LUG LANDING TO ACCEPT 2-600 M
  • 3MCB1600RBC-600 CH 1600A METERING MCB, 3 PH, WITH LUG LANDING TO ACCEPT 2-600 M
  • 3MCB1600RBC-600 CH 1600A METERING MCB, 3 PH, WITH LUG LANDING TO ACCEPT 2-600 M

Description: EATON Main Circuit Breaker, Type RGH 4-Wire Underground Feed, 120/208 VAC, 1600 A, 3 ph, RGH Frame, 65 kA Interrupt, NEMA 3R Enclosure, Line Side Lug Connection, 18.5 in L x 25.2 in W x 57.2 in H Dimensions

Manufacturer PN: 3MCB1600RBC-600

UPC:  78668517797

Kendall Electric Inc PN: 3884075

Invoice Description:

3MCB1600RBC-600 CH 1600A METERING MCB, 3 PH, WITH LUG LANDING TO ACCEPT 2-600 M


SPEC SHEET

▸ See All in Main Circuit Breaker Modules

 

EATON 3MCB1600RBC-600 Type RGH 4-Wire Underground Feed Main Circuit Breaker With Copper Bus, 120/208 VAC, 1600 A, 3 Phase

Log In for Pricing and Availability

Note: Lead times are estimates only

 
 

Description

EATON Arc flash reduction maintenance system (ARMS) for group metering main breakers enhances worker safety in multi-tenant residential and light commercial applications by reducing the arc flash potential while performing maintenance. With a reduction in arc flash hazard risk, workers can operate with improved mobility without sacrificing safety. ARMS provides accelerated instantaneous trip, reducing potential arc flash. 310+ trip unit provides the fastest clearing times in the industry, with less arc energy.
EATON Main Circuit Breaker, Type RGH 4-Wire Underground Feed, 120/208 VAC, 1600 A, 3 ph, RGH Frame, 65 kA Interrupt, NEMA 3R Enclosure, Line Side Lug Connection, 18.5 in L x 25.2 in W x 57.2 in H Dimensions

Specifications

 Amperage Rating 1600 A
 Application Commercial, Institutional Buildings, Structures, Building Automation and Monitoring Applications
 Brand Name EATON
 Connection Type Line Side Lug
 Dimensions 18.5 in L x 25.2 in W x 57.2 in H
 Enclosure NEMA 3R
 Frame RGH
 Manufacturer Part Number 3MCB1600RBC-600
 PART NUMBER KEYWORDS 3MCB1600RBC-600 ; 3MCB1600RBC600 ; 9851037 ; 786685177977 ; 78668517797 ; 00786685177977
 Phase 3
 Standards/Approvals UL Listed
 Type Type RGH 4-Wire Underground Feed
 Voltage Rating 120/208 V AC

Features

▪ Used with 800 A residential modular stacks, but only as a center fed main