Description: EATON Main Lug Loadcenter, 3-Phase Metallic, 120/208Y/240 V AC, 200 A, 42 Pole, 25 kA Interrupt, 42 Circuits, BR/BWH Breaker, 4-Wire Wiring Configuration, 42 Spaces, 1 AWG to 300 kcmil Wire, Flush Mount, NEMA 1, NEMA L1 Enclosure Box, 3.88 in L x 14.31 in W x 40.7 in H

Manufacturer PN: 3BR4242L200

UPC:  78667644250

Kendall Electric Inc PN: 2186853

Invoice Description:

3BR4242L200 CH 42 CIRCUIT ML 3P 200 AMP NEMA 1 LOADCENTER


SPEC SHEET

▸ See All in Three Phase Main Lug Load Centers

 

EATON 3BR4242L200 3-Phase Metallic Main Lug Loadcenter, 120/208Y/240 V AC, 200 A, 42 Poles, 25 kA Interrupt

Log In for Pricing and Availability

 
 

Description

Specially designed for easy installation, Eaton's BR 1-inch load centers house the branch circuit breakers and the wiring required to distribute power to individual circuits. They serve as main breaker for service entrances or as main lug when adding circuits to existing service. The main breaker protects the entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets.
EATON Main Lug Loadcenter, 3-Phase Metallic, 120/208Y/240 V AC, 200 A, 42 Pole, 25 kA Interrupt, 42 Circuits, BR/BWH Breaker, 4-Wire Wiring Configuration, 42 Spaces, 1 AWG to 300 kcmil Wire, Flush Mount, NEMA 1, NEMA L1 Enclosure Box, 3.88 in L x 14.31 in W x 40.7 in H

Specifications

 Amperage Rating 200 A
 Application Electrical Assemblies, Panels and OEMs Applications
 Brand Name EATON
 Breaker Type BR/BWH
 Dimensions 3.88 in L x 14.31 in W x 40.7 in H
 Enclosure NEMA 1
 Enclosure Box Size NEMA L1
 Includes Cover
 Manufacturer Part Number 3BR4242L200
 Mounting Type Flush
 Number of Circuits 42
 Number of Poles 42
 Number of Spaces 42
 Standards/Approvals UL 67,UL 50
 Type 3-Phase Metallic
 Voltage Rating 120/208Y/240 V AC
 Wiring Configuration 4-Wire

Features

▪ No feed through lugs
▪ Combination mounting
▪ Flexible neutral design
▪ Tangential main knockout
▪ Single key hole mounting
▪ Factory pre-attached neutral bonding strap
▪ Bottom or top feed location
▪ For use with type BR 1 in breakers
▪ Indoor enclosure
▪ Copper aluminum wire at 60 to 75 deg C for main lugs
▪ Standard tin plated aluminum bus for excellent conductivity and corrosion-resistance
 